Model: | SVD-PS2.2GB | Phase: | Single Phase 220v |
---|---|---|---|
Max O/P Frequency: | Vector Control:0--300Hz V/F Control: 0--3200Hz | Power Capacity: | 2.5 Kva |
Input Current: | 13.8 A | Output Current: | 7.4 A |
Adaptable Motor: | 1.45KW,2HP | Thermal Power Consumption: | 0.058kw |
High Light: | 2.2kw DC To AC VFD Drives,7.4A DC To AC VFD Drives,2.2kw AC Drive Inverter |
Product Description
Single Phase 2.2kw DC To AC VFD Drives Customizable Simple Install
Customizable Install Simple 2.2kw Dc To Ac single Phase Ac Drive Inverter
Product Description
Multiple communication protocols
It supports communication via Modbus-RTU, PROFIBUS-DP, CANlink and CANopen.
Multiple encoder types
It supports various encoders such as differential encoder, open-collector encoder, resolver and UVW encoder.
All-new SFVC algorithm
It introduces an all-new sensorless flux vector control (SFVC) algorithm that gives better low-speed stability, enhanced low-frequency loading capacity, and supports torque control.
User programmable function
The SPPC1 programmable card enables you to write programs in ladder diagram. Its programming environment is compatible with that of the H1U series PLC.
Advanced background software
The background monitoring software helps to achieve functions of parameter upload &
download and a real-time oscilloscope.
Features
SFVC/CLVC/VF
High Start Torque
Fast Dynamic
High Frequency & Torque stability
Flexible
Cost-effective
Housing types for different voltage and power classes
Voltage & Power Class | Housing Type |
Single-phase 220 V | |
0.4–2.2 kW | Plastic housing |
Three-phase 220 V | |
0.4–7.5 kW | Plastic housing |
11–75 kW | Sheet metal housing |
Three-phase 380 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 480 V | |
0.75–15 kW | Plastic housing |
18.5–400 kW | Sheet metal housing |
Three-phase 690 V | |
55–500 kW | 55–500 kW |
Item | Specification | |
Standard functions | Max O/P frequency | • Vector control: 0–300 Hz • V/F control: 0–320 Hz |
Carrier frequency | 0.5–16 kHz automatically adjusted according to the load features. | |
I/P Freq. resolution | Digital setting: 0.01 Hz, Analog setting: maximum frequency x 0.025% | |
Control mode |
• Sensorless flux vector(SFVC) • Closed-loop vector(CLVC) • V/F |
|
Startup torque | • G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) • P type: 0.5 Hz/100% | |
Speed range | 1:100 (SFVC) 1:1000 (CLVC) | |
Speed stability | • ± 0.5% (SFVC) • ± 0.02% (CLVC) | |
Torque accuracy | ± 5% (CLVC) | |
Overload capacity | • G type: 60s for 150%, 3s for 180% • P type: 60s for 120%, 3s for 150% | |
Torque boost | • Fixed boost • Customized boost 0.1%–30.0% | |
V/F curve | • Straight-line V/F curve • Multi-point V/F curve • N-power V/F curve | |
Ramp mode | • Straight-line • S-curve • 4 groups of ac/decceleration time 0.0–6500.0s | |
DC braking | •frequency: 0.00 Hz to Max Freq • Time: 0.0–36.0s | |
JOG control | Frequency: 0.00–50.00 Hz acceleration/deceleration time: 0.0–6500.0s | |
Voltage regulation | Maintain output voltage against the input mains voltage fluctuation. | |
Stall control | Smart current and voltage regulation to avoid tripping OCP/OVP | |
Torque limit | Smart Torque regulation to avoid tripping OCP | |
Enhanced functions | High performance | High-performance current vector control technology. |
Power dip ride through | Manage speed of motor to ride through short period power interruption | |
Rapid current limit | It helps to avoid frequent overcurrent faults of the AC drive. | |
Virtual I/Os | Five groups of virtual DI/Dos can realize simple logic control. | |
Timing control | Time range: 0.0–6500.0 minutes | |
Multi-motor switchover | 4 motors with individual motor parameters. | |
Multi-communication | Modbus-RTU, PROFIBUS DP, CANopen. | |
Motor overheat protect | Accept the motor temperature sensor input for overheat protection. | |
Encoder types | supports: differential, open-collector ,resolver, UVW and SIN encoder | |
RUN | Command source | • Operation panel • Control terminals • Serial communication port |
Frequency source | Up to 10 sources | |
Input terminal | • 5 x DI (1 high-speed pulse) • 2 x AI (0–10 V/ or 4–20 mA) | |
• Extension : 5 x DI , 1 AI | ||
Output terminal | • 2 DO (1 high-speed pulse) • 1 relay • 1 AO 0–20 mA or 0–10 V Extension: 1 DO, 1 relay output, 1 AO 0–20 mA or 0–10 V |
|
Panel | Display | LED numeric displays with LED indicator |
Environment | operation temperature | .-10°C to 50°C derating needed between 40~50°C |
Humidity | 0~ 97%RH, non condensing | |
IP level | IP20 |