15kw 20hp 380v Variable Frequency Drives 50hz To 60hz Power Converter
Product Details:
Payment & Shipping Terms:
| Minimum Order Quantity: | 1 |
|---|---|
| Price: | $302 |
| Delivery Time: | 10-15 work days |
| Payment Terms: | L/C, Western Union, Western Union, T/T |
|
Detail Information |
|||
| Type: | DC/AC Inverters | Output Type: | 3-phase |
|---|---|---|---|
| Frequency Range: | ±5% (47.5 ~ 63Hz) | Output Frequency: | 0.1-500Hz |
| Nominal Capacity: | 15 KW | Vector Control: | 0–500 Hz |
| Highlight: | 380v Variable Frequency Drives,15kw Variable Frequency Drives,20hp 50hz To 60hz Power Converter |
||
Product Description
15kw 20hp 380v Variable Frequency Drives 50hz To 60hz Power Converter
15kw 20hp 380v ac variable frequency inverter 3-phase ac drive 50hz to 60hz power converter
Technical specifications of the SVD-P
| Item | Specifications | ||
|
Standard functions |
Maximum frequency |
• Vector control: 0–500 Hz • V/F control: 0–500 Hz |
|
|
Carrier frequency |
0.5–16 kHz The carrier frequency is automatically adjusted based on the load features. |
||
| Input frequency resolution |
Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
||
|
Control mode |
• Sensorless flux vector control (SFVC) • Closed-loop vector control (CLVC) • Voltage/Frequency (V/F) control |
||
|
Startup torque |
• G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) • P type: 0.5 Hz/100% |
||
| Speed range | 1:100 (SFVC) | 1:1000 (CLVC) | |
| Speed stability accuracy |
• ± 0.5% (SFVC) • ± 0.02% (CLVC) |
||
| Torque control accuracy |
± 5% (CLVC) |
||
variable frequency inverter Description
The SVD-P series AC drive is a general-purpose high-performance current vector control AC drive. It is an upgrade product based on SVD-E and can implement the control of asynchronous motor and permanent magnet synchronous motor (PMSM). It increases the user programmable function, background monitoring software and communication bus function, and supports multi-kind PG cards. It is used to drive various automation production equipment involving textile, paper-making, wiredrawing, machine tool, packing, food, fan and pump.
Housing types for different voltage and power classes
| Voltage & Power Class | Housing Type |
| Single-phase 220 V | |
| 0.4–2.2 kW | Plastic housing |
| Three-phase 220 V | |
| 0.4–7.5 kW | Plastic housing |
| 11–75 kW | Sheet metal housing |
| Three-phase 380 V | |
| 0.75–15 kW | Plastic housing |
| 18.5–400 kW | Sheet metal housing |
| Three-phase 480 V | |
| 0.75–15 kW | Plastic housing |
| 18.5–400 kW | Sheet metal housing |
| Three-phase 690 V | |
| 55–500 kW | 55–500 kW |
The newly added functions of the SVD-P series AC drive are described as below:
| Function | Description |
| Virtual I/O | It can implement various simple logic functions. |
|
Motor overheat protection |
The optional SP-IO1 extension card enables AI3 to receive the signal from the motor temperature sensor input (PT100, PT1000) thereby providing motor overheat protection. |
|
Rapid current limit |
It helps to avoid frequent occurrence of overcurrent faults of the AC drive. |
|
Multi-motor switchover |
Four motors can be switched over via four groups of motor parameters. |
|
Restoring user parameters |
It allows you to save or restore the parameters set by yourself. |
|
Higher-accuracy AI/AO |
The AI/AO accuracy can reach almost 20 mv via factory correction or on-site correction. |
| Customized parameter display | You can customize the parameters that need to be displayed. |
| Modified parameter display | You can view the modified parameters. |
|
Operation selection at fault occurrence |
You can select the reaction of the AC drive to a fault occurring, based on the actual need. The reactions are as below: • Coast to stop • Decelerate to stop • Continue to run You can also select the frequency at which the AC drive continues to run. |
|
PID parameters switchover |
Two groups of PID parameters can be switched over via terminals or can be automatically switched over according to deviation. |
|
PID feedback loss detection |
The PID feedback loss value can be set to realize PID protection. |
| DI/DO positive or negative logic |
You can set the DI/DO positive or negative logic. |
| DI/DO response delay | You can set DI/DO response delay time. |
|
Power dip ride through |
It ensures that the AC drive continues to run for a short time when an instantaneous power failure or sudden voltage reduction occurs. |
|
Timing operation |
The AC drive supports timing operation for 6500 minutes at maximum. |
|
User programmable function |
The externally connected programmable card helps you to realize secondary development. |
|
Load allocation |
Load allocation can be implemented between two SVD-P series AC drives through point-to-point communication. |
![]()
![]()
![]()
![]()
![]()