Rated Voltage: 380/400/415 Vac Three-phase Frequency Range: 45-65Hz
Protection Degree: IP20 Efficiency Smart Mode: Up To 98%
Capacity: 8KW 12KW 16KW 24KW 32KW 48KW 64KW 80KW 96KW 128KW 160KW Power: 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA
High Light:

Modular Online UPS 80KW

,

12KW Modular Online UPS

,

Uninterruptible Power Supply Low Frequency Online UPS

Product Description

Low Frequency Online Modular UPS 100KVA Module Uninterruptible Power Supply UPS System

The UPS consists of the following subassemblies:

RECTIFIER

Standard is six pulse rectifier, optional is twelve pulse to reduce input current distortion.

Represents the input stage and transforms the alternating voltage of the power line in continuous voltage. The

functions carried out by the rectifier are the following:

- powering the inverter with direct current.

- charging the battery automatically. Battery charging is done in two phases: the first phase supplies 80% of

power with limited current (recharging current) and growing voltage. The second supplies the remaining 20%

of the charge with steady voltage (holding).

Recharging current is automatically limited to 15% of the capacity in Ah contained in the memory. This recharging

current imposed applies only when the total power delivered to the battery and the load does not exceed maximum

110% of Pn.

 

HARMONIC REDUCTION FILTER (optional)

The filter is positioned to the entry of the rectifier, allows to reduce the input harmonic distortion of the input current.

It is composed by two inductors and by a group of capacitors. The filter is protected in entry with some fusible.

 

EXTERNAL BATTERY

Provides the reserve energy for powering the load when there is no power input to the UPS.

 

INVERTER

This is the output stage. Converts direct voltage from the RECTIFIER or BATTERY into stabilized sinusoidal

alternating voltage. It is always in operation and the load connected to the output of the UPS is always powered by the

INVERTER.

 

STATIC SWITCH

This device allows the instantaneous automatic or manual switching of the power feed from the secured line

(INVERTER output ) to an unsecured line (BY-PASS line) or vice versa.

The STATIC SWITCH is supplied with a device, BACKFEED PROTECTION that prevents the danger of current

returns on the reserve line, in the case of Mains power failure due to a break on the SCR. The SCR are protect by

FSCR fuses.

 

SWMB

Maintenance switch, by closing the SWMB and opening the other switches SWIN, SWBY, SWOUT the UPS is excluded, maintaining the output feed.

This operation is necessary when you have to carry out maintenance operations inside the equipment, without being obliged to interrupt the power feed.

With the SWMB closed and all the other switches open, there is no voltage inside the equipment (voltages are present only in the terminal board area and in the switches area, N.B. in the threephase output version the neutral conductor is not interrupted.).

Uninterruptible Power Supply Modular Online UPS 100KVA Low Frequency 0Uninterruptible Power Supply Modular Online UPS 100KVA Low Frequency 1Uninterruptible Power Supply Modular Online UPS 100KVA Low Frequency 2Uninterruptible Power Supply Modular Online UPS 100KVA Low Frequency 3

Want to Know more details about this product
I am interested in Uninterruptible Power Supply Modular Online UPS 100KVA Low Frequency could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.