High Frequency 1KVA 110V 120V Double Conversion UPS For Home Use
Product Details:
Place of Origin: | Guangdong, China |
Brand Name: | ZGD |
Certification: | CE ROHS |
Model Number: | C1K |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 sets |
---|---|
Price: | $129.00/Sets 1-29 Sets |
Packaging Details: | Carton packaging |
Delivery Time: | 7~15 working days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000 Set/Sets per Month |
Detail Information |
|||
Weight: | 11.8KG | Application: | Home |
---|---|---|---|
Capacity: | 1KVA | Input Voltage: | 220V |
Output: | 220VAC | Type: | On-line |
High Light: | 120V Double Conversion UPS,1KVA High Frequency UPS,1KVA Home Use UPS |
Product Description
High Frequency 1KVA 110V 120V Double Conversion UPS For Home Use
High Frequency Ups 1KVA 110V 120V Online Double Conversion Ups For Home Use
1. This UPS contains its own energy source (batteries). The UPS output may carry live voltage even when the UPS is not connected to an AC supply.
2. To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40°C (104°F). Do not operate near water or excessive humidity (90% maximum).
3. To reduce the risk of fire, connect only to a circuit provided with branch circuit over-current protection . Output overcurrent protection and disconnect switch must be provided by others.
4. To comply with international standards and wiring regulations, the sum of the leakage current of the UPS and the total equipment connected to the output of this UPS must not have an earth leakage current greater than 3.5 milliamperes.
5. If installing optional rack-mount Battery Pack, install the Battery Pack directly below the UPS so that all wiring between the cabinets is installed behind the front covers and is inaccessible to users.
Specification
Model item |
1K(R) |
1K(R)S |
2K(R) |
2K(R)S |
3K(R) |
3K(R)S |
6K |
6K(R)S |
10K |
10K(R)S |
|
Rated power |
1000VA/800W |
2000VA/1600W |
3000VA/2400W |
6kVA/5.4kW |
10kVA/9kW |
||||||
AC Input |
Input system |
Single phase (L/N+PE) |
|||||||||
|
Nominal voltage |
HV: 208/220/230/240Vac LV:100/110/120/127Vac |
|||||||||
|
Frequency |
50/60Hz |
|||||||||
|
Voltage range |
HV: 90~300VAC±5VAC LV: 60-145Vac±3VAC |
|||||||||
|
Frequency range |
(40~70)±0.5Hz |
|||||||||
|
Input power factor |
>0.99 |
|||||||||
|
Bypass Voltage Range |
HV: 115~285VAC×(1±3%) LV: 80~140VAC×(1±3%) |
|||||||||
Battery Input |
Nominal Voltage |
24V |
36V |
48V |
72V |
72V |
96V |
192V |
192V |
192V/240V |
|
|
Battery Capacity & Quantity |
12V/9AH x 2pcs |
External |
12V/9AH x 4pcs |
External |
12V/9AH x 6pcs |
External |
12V/9AH x 16pcs |
External |
12V/9AH x16/20pcs |
External |
|
Backup Time |
Half loaded≥8minutes, Full loaded ≥3minutes(standard) |
Half loaded≥6minutes, Full loaded ≥3minutes(standard) |
||||||||
|
Battery charger time |
Charger to 90% battery capacity in 5 hours(standard) Dependent on the capacity of external batteries (long backup time) |
|||||||||
AC Output |
Output system |
Single phase (L/N+PE) |
|||||||||
|
Inverter Mode Output voltage |
HV:208/220/230/240Vac±2% LV:100/110/120/127Vac±2% |
|||||||||
|
Waveform |
Sine Wave THD<3% (linear load) THD<7% (nonlinear load) |
Sine Wave THD<2% (linear load) THD<5% (nonlinear load) |
||||||||
|
Output frequency |
50/60±4Hz (Sync mode) 50/60Hz±1% (Fix Freq. mode) |